LU
CPU
Art.3176 Telephones
4 way junction box
Landing Unit
SP400 control cabinet
VX22
00 digital or
functional door panel
Monitored 12Vdc fail
secure or fail open lock
release
Product Key
VX2200 Block Diagram
1 Audio entrance to multiple apartments using Art.3176 telephones
Min. cable requirements
Max. distance 100m
3 Pair
AWG22 (0.325mm²)
Re
sistance/km 54.12Ω
6 Pair
AWG22 (0.325mm²)
Resistance/km 54.12Ω
Max. distance 200m
3 Pair
AWG20 (0.5mm²)
Resistance/km 32.8Ω
6 Pair
AWG20 (0.5mm²)
Resistance/km 32.8Ω
Max. distance 350m
3 Pair
AWG18 (0.8mm²)
Resistance/km 19.2Ω
6 Pair
AWG18 (0.8mm²)
Resistance/km 19.2Ω
Consult the VX2200 cable guide for
more information
7
4
4
7
4
7
Notes:
Two extra cores required to the telephone’s if
the local door bell facility is required (Not
available on isolation systems)
VIDEX SECURITY LTD, UNIT 4-7 CHILLINGHAM IND. EST., NEWCASTLE
UPON TYNE, NE6 2XX
TEL 0870 300 1240 FAX 0191 224 5678 E-MAIL SALES@VIDEX-
SECURITY.COM WEB WWW.VIDEX-SECURITY.COM
CPU